Ask for a comparable baseline
Identify the formula revision, batch, filling date and pack. Agree when the initial reading will be taken after filling and how long samples will rest after transport. Specify whether the laboratory will withdraw material from an unopened pack or measure it in its original container. Reserve enough separate packs for repeats.
Make the method part of the quotation
Request the instrument, spindle or measuring geometry, speed or shear rate, sample temperature, equilibration time, and the point at which the reading is taken. Creams and gels can thin under shear. Results at different speeds can therefore describe different behaviour, even when both are reported in mPa·s.
Read a change against the product
Ask for individual readings and observations alongside the average. If a stored cream dispenses differently, record the dose from the intended pump and look for separation before mixing the sample. Where the setup has changed, arrange a side-by-side repeat under the agreed conditions. Define any acceptance limits for the specific formula and pack.